Home / Chemicals & Minerals / Environment / LUFH Laminar Airflow System

LUFH Laminar Airflow System

Laminar flow is an air purification device that provides Class A unidirectional flow and creates a locally high cleanliness environment.

Category: Environment
Share This :
  • Description
  • Reviews (0)

Description

Class A one-way flow hood is an air purification equipment that provides
class A one-way flow and creates a local high cleanliness environment. Its
working principle is to pass the air through the high-efficiency filter at a
certain wind speed, and then equalize the pressure through the damping layer, so
that the clean air flow is sent to the work area in a unidirectional flow, so as
to obtain the required flow pattern and cleanliness of the work protection area.
Class A unidirectional flow hood can be used singly or in combination. The
working area of the class A unidirectional flow hood is the sterile core area.
The operator needs to open the equipment from the class B background area
environment according to the defined SOP, and perform process operations and
interventions. These actions need to be formulated according to the risk to the
product. The operator should avoid contact with the sterile core, if it needs to
be contacted, it should be through isolating gloves or half-dress.

Model

Dimensions(mm)(L×W×D)

Work area size(mm)(L×W)

Air outlet
rated air speed(m/s)

Work area
cleanliness(grade)

Noise(dB)

Illumination(Lx)

Power( K W )

LUFH12-120.60*

1200×600×600

1200×600

0.45±20%

A

65~75

300~500

0.3

LUFH16-100 100*

1000×1000×600

1000×1000

0.45

LUFH24-120 120*

1200×1200×600

1200×1200

0.6

LUFH32-200.100*

2000×1000×600

2000×1000

0.9

LUFH48-120.120*

1200×1200×600

1200×1200

1.2

LUFH65-200.200*

2000×2000×600

2000×1000

1.8

Note:The specficationsited in the table are only for reference.Most class A
unidretional laminar Flow hoods are designed and manufactured according to URS
of customers.

HEPA ensures low resistance, high efficiency, and more reliable liquid tank sealing.

Internally and externally consistent, clean and without any dead corners.

Rich control forms to meet different customer requirements. Multiple pressure equalization, uniform wind speed, and good unidirectional flow pattern. Imported fan, high residual pressure, low noise and energy-saving, reliable performance.

The design is simple, the maintenance cost is low, and it provides an efficient A-class clean environment,. Can be used for the assembly, testing, inspection, and other production processes of sterile products that require ultra cleanliness. Integrated fan filter module with low noise.

Product schematic diagram:

1.Outer casing 2. Inner box 3. Fan 4. Return air orifice plate 5. Plate initial effect

6. Uniformity membrane 7. DOP dust outlet 8. Differential pressure gauge

9. DOP sampling port 10. Efficient liquid tank 11. Lighting fixtures

1.Outer casing 2. Inner box 3. Fan 4. Return air orifice plate 5. Plate initial effect

6. Uniformity membrane 7. DOP dust outlet 8. Differential pressure gauge

9. DOP sampling port 10. Efficient liquid tank 11. Lighting fixtures

Reviews

There are no reviews yet.

Be the first to review “LUFH Laminar Airflow System” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

  • Add To Cart
    KSZ-3.0D1/D2 welding exhaust hose

    KSZ-3.0D1/D2 welding exhaust hose

    KSZ-3.0D1/D2 welding exhaust hose Features:
    ● High efficiency custom aluminum impeller
    ● Self-supporting & self-positioning suction hood
    ● Durable flexible suction arm, high temperature resistance & flame retardant & abrasion resistance
    ● Easy to replace and clean filters, no frequent maintenance is required
    ● Imported filter material with high precision filtration
    ● Special designed dust cleaning device, automatic blow-back cleaning
    ● Siemens PLC smart control system, more intelligent and energy saving
    ● Integrated automatic fire extinguish system

    Category: Environment
  • Add To Cart
    RTO regenerative thermal oxidizer for removing VOCS

    RTO regenerative thermal oxidizer for removing VOCS

    RTO is an air pollution control system which collecting the exhausted air through the safety air valve into the oxidation bed with the temperature over 820℃ to oxidation the organic waste gas into carbon dioxide and water.
    It is used
    1. Industrial and mining conditions with high and low concentrations of organic solvents in the treatment of emitted gases
    2. Industrial and mining conditions with requirements for the collection and treatment of unorganized emissions
    3. Equipment conditions without waste heat utilization value

    Category: Environment
  • Add To Cart
    NGB High Temperature-resistant 350℃ Separator HEPA Filter

    NGB High Temperature-resistant 350℃ Separator HEPA Filter

    The filter material is high temperature resistant ultra-fine glass fiber filter paper, and the separator is aluminum foil corrugated sheet.

    Category: Environment
Recent
  • Educational Kids Claw Machine Toy with Lights and Sounds – Interactive Game for Skill Development)
  • White Colors Micro Denier Fiber For High End Padding
  • Heavy duty sliding door
  • Zener Diode
You May Be Interested
  • Wireless Audio System Multiroom 360 $2,299.00
  • Laptop R752LJ 17,3” 5200U 4GB 1TB $1,100.00
  • YApple MacBook 12 $1,000.00
  • Notebook Widescreen Y700-17 GF790 $1,000.00
Product
  • Vehicle Air Conditioners——48V DC Ducted type air conditioner
  • Traffic command RC-02
  • Modular Energy Storage System
  • Beauty Mask Mold
Proudly powered by WordPress | Theme: eCommerce Lite by Spiderbuzz.
    • Home
    • News
    • Shop
    • Contact Us